Copyright: Wuhan Nanxing Power Technology Co., Ltd. 鄂ICP备06008607号
Website:300.cn Wuhan
LED3000 visual anti-interference leak detector
basic information
Detailed parameters
Features:
● NDS5000 anti-interference full-featured version can detect gas leak detection, electrical discharge, vacuum and negative pressure leak detection, leak detection, steam trap system, valve internal leak detection, bearing inspection, equipment auscultation, temperature measurement and visual photographing ( Superior ability to shield environmental interference);
● Visualized ultrasonic leak detection instrument During the moving scan process, the sensor will display on the large color LCD screen after detecting the leak signal. The source of the leak on the LCD screen is yellow (indicating a small leak, the signal is weak) or red (indicating a large leak, strong signal) real-time visible image. At the same time, the horizontal beam at the bottom of the LCD screen is displayed in different colors and values.
The main parameters:
Host parameter
|
Detection sensitivity
|
100 Feet (About 30 meters), pressure 1bar, 0.01mm leak point
|
Method of judging leakage
|
Sound + value + color bar + leak point automatically display image
|
|
Pixel
|
640×480
|
|
LCD color display
|
3,5 inch "320×240 connection method: USB interface
|
|
Lks storage
|
Can store 1000 test data, which can be downloaded to the computer for analysis
|
|
Auscultation adjustment
|
Volume can be adjusted from 0 to 10
|
|
Precision
|
+/-0.3dBuV
|
|
US sensor
|
Band
|
+/- 2kHz à - 6 dB
|
Central frequency
|
40 kHz +/-1 kHz
|
|
Mixer frequency
|
34 ~46 kHz
|
|
Gain
|
50~110DB
|
|
Dimensions
|
230×100×70 mm,About 500g
|
keywords:
On a